Liquids
Direct excitation for liquid mixing, movement and process conditioning.
Powerful pneumatic resonance delivered directly inside the process medium. Immersion units form a separate product family for liquids, wet processing, mixing, underwater work and special industrial environments.

Immersion configuration, contact materials, pneumatic supply, depth, mounting and operating cycle are reviewed as one system.
Direct excitation for liquid mixing, movement and process conditioning.
Application-specific systems for environments where external dry mounting is not the right energy path.
Pneumatic architecture suited to fully submerged industrial applications when correctly configured.
Excitation can be introduced inside wet materials where process geometry requires it.
Minimal maintenance architecture avoids routine lubrication inside demanding operating zones.
Hoses, supports and contact arrangements are engineered around the medium and access.
Share the medium, temperature, depth, vessel geometry, duty cycle and measurable process objective.
Historical manufacturer-declared source values. They are not confirmed ratings for current RVS/RVI configurations. No direct mapping to modern model classes is established. Confirm the delivered unit, test conditions and installation before selection.
| Source model | Pressure · bar | Declared force · N | Frequency · Hz | Air · m³/min¹ |
|---|---|---|---|---|
| RFB 1 | 2 | 3 000 | 320 | 0.3 |
| RFB 1 | 4.5 | 7 000 | 500 | 0.7 |
| RFB 1 | 7 | 9 500 | 570 | 1 |
| RFB 2 | 2 | 3 800 | 170 | 0.38 |
| RFB 2 | 4.5 | 9 500 | 270 * | 0.8 |
| RFB 2 | 7 | 13 000 | 350 | 1.3 |
| Source model | Source length | Mass |
|---|---|---|
| RFB 1 | 470 mm | 6 kg |
| RFB 2 | 530 mm | 9.5 kg |
* RFB 2 at 4.5 bar: the source lists 270 Hz and 15,000/min, which do not agree exactly. Hz is reproduced as stated; verification is required. The source label for D is ambiguous, so a diameter and working radius are not specified here.
¹ Air consumption is reproduced in source units; reference conditions and measurement method need confirmation. It is not a compressor-sizing guarantee.